Hydraulic flushing powerpacks for food industry
Double pump with fixed displacement
Aluminum tank
Cadmium plated rigid pipes
partager sur
Environmental condition | ||
Voltages | ||
Line voltages | (V) | 400 |
Frequency | (Hz) | 50 |
Solenoids voltage | (V) | 24 DC |
Power connection | ||
Installed power | (kW) | 0,4 |
Protection degree | (A) | 1,4 |
Protection degree | (IP) | 55 |
Flow rates mouths / uses | ||
Use (P) | ||
Max pressure | (bar) | 14 |
Max flow | (limin) | 9,5 |
Use (T) | ||
Max pressure | (bar) | discharge line |
Max flow | (limin) | discharge line |
Use (Water in) | ||
Max pressure | (bar) | 12 |
max flow | (limin) | |
Use (Water out) | ||
Max pressure | (bar) | 12 |
Max flow | (limin) |