Powerpack with external protection for marine applications
- Gear pump with fixed displacement.
- Tank to design with external protection from atmospheric agents.
- Powerpack lifting system by crane.
- Arrangement for customer's electrical panel under the cover.
- Structure and components painting of marine type high thickness.
partager sur
| Environmental conditions | |||
| Operating temperature | (°C) | 0 -> +45 | |
| Storage temperature | (°C) | -10 -> +70 | |
| Humidity | % | 10 -> 90 | (not condesed) |
| Weight | |||
| Weight without oil | (Kg) | 350 | |
| Voltage | |||
| Line voltage | (V) | 400 | |
| Frequency | (Hz) | 50 | |
| Power connections | |||
| Installed power | (kW) | 11 | |
| Protection | (IP) | 56 | Motors protection |
| Hydraulic features | |||
| Circuit | |||
| Max pressure | (bar) | 240 |